All Issue

2020 Vol.14, Issue 2

Research Article

30 April 2020. pp. 147-157
Abstract
References
1
Beier, R.A., Smith, M.D., Spitler, J.D. (2011). Reference data sets for vertical borehole ground heat exchanger models and thermal response test analysis. Geothermics, 40(1), 79-85.
10.1016/j.geothermics.2010.12.007
2
Cao, X., Yuan, Y., Sun, L., Lei, B., Yu, N., Yang, X. (2015). Restoration performance of vertical ground heat exchanger with various intermittent ratios. Geothermics, 54, 115-121.
10.1016/j.geothermics.2014.12.005
3
Cui, P., Yang, H., Fang, Z. (2008). Numerical analysis and experimental validation of heat transfer in ground heat exchangers in alternative operation modes. Energy and Buildings, 40(6), 1060-1066.
10.1016/j.enbuild.2007.10.005
4
Jalaluddin, Miyara, A. (2012). Thermal performance investigation of several types of vertical ground heat exchangers with different operation mode. Applied Thermal Engineering, 33, 167-174.
10.1016/j.applthermaleng.2011.09.030
5
Marcotte, D., Pasquier, P. (2008). On the estimation of thermal resistance in borehole thermal conductivity test. Renewable Energy, 33(11), 2407-2415.
10.1016/j.renene.2008.01.021
6
Philippe, M., Bernier, M., Eng, P., Marchio, D. (2010). Sizing calculation spreadsheet: Vertical geothermal borefields. Ashrae J., 52, 20-28.
7
Shirazi, A.S., Bernier, M. (2013). Thermal capacity effects in borehole ground heat exchangers. Energy and Buildings, 67, 352-364.
10.1016/j.enbuild.2013.08.023
8
Curtis, R., Pine, T., Wickins, C. (2013). Development of new ground loop sizing tools for domestic GSHP installations in the UK. In European Geothermal Congress 2013, 1-10.
9
Gultekin, A., Aydın, M., Sisman, A. (2014). Determination of Optimal Distance Between Boreholes. In Thirty-Ninth Workshop on Geothermal Reservoir Engineering, Stanford, California, 1-8.
10
He, M., Rees, S., Shao, L. (2009). Applications of a dynamic three-dimensional numerical model for borehole heat exchangers. 11th International Conference on Thermal Energy Storage.
11
Xu, X., Spitler, J.D. (2006). Modeling of vertical ground loop heat exchangers with variable convective resistance and thermal mass of the fluid, in: Multipole Method to Comput. Conduct. Heat Flow to between Pipes A Compos. Cylind, In Proceedings of the 10th International Conference on Thermal Energy Storage. Ecostock.
12
Eskilson, P. (1987). Thermal Analysis of Heat Extraction Boreholes. Ph.D thesis. University of Lund, Lund, Sweden.
13
American Society of Heating Refrigerating and Air-Conditioning Engineers (ASHRAE). (2011). 2011 ASHRAE Handbook - HVAC Applications - SI. Atlanta: Refrigerating and Air-Conditioning Engineers, American Society of Heating.
14
Verein Deutscher Ingenieure (VDI). (2015). Verein Deutscher Ingegneure: VDI 4640 - Blatt 2. Thermal use of the underground - Ground source heat pump systems.
Information
  • Publisher :Korean Institute of Architectural Sustainable Environment and Building Systems
  • Publisher(Ko) :한국건축친환경설비학회
  • Journal Title :Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
  • Journal Title(Ko) :한국건축친환경설비학회논문집
  • Volume : 14
  • No :2
  • Pages :147-157
  • Received Date : 2019-05-19
  • Revised Date : 2020-04-17
  • Accepted Date : 2020-04-19
Journal Informaiton Journal of Korean Institute of Architectural Sustainable Environment and Building Systems Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
  • NRF
  • KOFST
  • KISTI Current Status
  • KISTI Cited-by
  • crosscheck
  • orcid
  • open access
  • ccl
Journal Informaiton Journal Informaiton - close